You have been subscribed to a public bug:
Battery power status only gets updated on insertion and removal of the
ac adapter on an Acer Travelmate 4500 series notebook. Other than that
is't stuck at the same level. lshal -m only displays activity on the
above mentioned events. Contents of /proc/acpi/battery/BAT1/ and
/sys/class/power_supply/BAT1/ displays same behavior.
ndlar...@lapslave:~$ lsb_release -rd
Description: Ubuntu jaunty (development branch)
Release: 9.04
ndlar...@lapslave:~$ apt-cache policy linux-image-2.6.28-7-generic hal acpi
acpid
linux-image-2.6.28-7-generic:
Installed: 2.6.28-7.20
Candidate: 2.6.28-7.20
Version table:
*** 2.6.28-7.20 0
500 http://dk.archive.ubuntu.com jaunty/main Packages
100 /var/lib/dpkg/status
hal:
Installed: 0.5.12~rc1+git20090204-0ubuntu1
Candidate: 0.5.12~rc1+git20090204-0ubuntu1
Version table:
*** 0.5.12~rc1+git20090204-0ubuntu1 0
500 http://dk.archive.ubuntu.com jaunty/main Packages
100 /var/lib/dpkg/status
acpi:
Installed: 1.2-1ubuntu1
Candidate: 1.2-1ubuntu1
Version table:
*** 1.2-1ubuntu1 0
500 http://dk.archive.ubuntu.com jaunty/universe Packages
100 /var/lib/dpkg/status
acpid:
Installed: 1.0.6-9ubuntu4
Candidate: 1.0.6-9ubuntu4
Version table:
*** 1.0.6-9ubuntu4 0
500 http://dk.archive.ubuntu.com jaunty/main Packages
100 /var/lib/dpkg/status
ndlar...@lapslave:~$ uname -a
Linux lapslave 2.6.28-7-generic #20-Ubuntu SMP Mon Feb 9 15:43:21 UTC 2009 i686
GNU/Linux
Output of lshal -m on insertion of ac adapter:
Start monitoring devicelist:
-------------------------------------------------
11:16:06.258: computer_power_supply_ac_adapter_sbs_charger property
ac_adapter.present = true
11:16:06.653: computer property power_management.is_powersave_set = false
11:16:31.005: computer_power_supply_battery_BAT0 property
battery.remaining_time = 32449 (0x7ec1)
11:16:31.011: computer_power_supply_battery_BAT0 property
battery.charge_level.percentage = 19 (0x13)
11:16:31.015: computer_power_supply_battery_BAT0 property
battery.charge_level.rate = 3581 (0xdfd)
11:16:31.018: computer_power_supply_battery_BAT0 property
battery.charge_level.current = 12432 (0x3090)
11:16:31.028: computer_power_supply_battery_BAT0 property
battery.reporting.current = 840 (0x348)
11:16:31.036: computer_power_supply_battery_BAT0 property
battery.rechargeable.is_discharging = false
11:16:31.044: computer_power_supply_battery_BAT0 property
battery.rechargeable.is_charging = true
11:16:31.051: computer_power_supply_battery_BAT0 property
battery.reporting.rate = 242 (0xf2)
11:16:31.053: computer_power_supply_battery_BAT0 property
battery.voltage.current = 15010 (0x3aa2)
Same on removal of the ac adapter:
Start monitoring devicelist:
-------------------------------------------------
11:45:08.280: computer_power_supply_ac_adapter_sbs_charger property
ac_adapter.present = false
11:45:08.998: computer property power_management.is_powersave_set = true
11:45:11.004: computer_power_supply_battery_BAT0 property
battery.remaining_time = 1855 (0x73f)
11:45:11.007: computer_power_supply_battery_BAT0 property
battery.charge_level.percentage = 45 (0x2d)
11:45:11.009: computer_power_supply_battery_BAT0 property
battery.charge_level.rate = 29437 (0x72fd)
11:45:11.011: computer_power_supply_battery_BAT0 property
battery.charge_level.current = 29540 (0x7364)
11:45:11.013: computer_power_supply_battery_BAT0 property
battery.reporting.current = 1996 (0x7cc)
11:45:11.015: computer_power_supply_battery_BAT0 property
battery.reporting.rate = 1989 (0x7c5)
11:45:11.017: computer_power_supply_battery_BAT0 property
battery.voltage.current = 16509 (0x407d)
ndlar...@lapslave:~$ hal-device `hal-find-by-capability --capability "battery"`
udi = '/org/freedesktop/Hal/devices/computer_power_supply_battery_BAT1'
battery.present = false (bool)
linux.sysfs_path =
'/sys/devices/LNXSYSTM:00/device:00/PNP0A03:00/device:0b/PNP0C09:00/ACPI0001:00/ACPI0002:00/power_supply/BAT1'
(string)
info.parent = '/org/freedesktop/Hal/devices/computer' (string)
info.subsystem = 'power_supply' (string)
info.product = 'Generic Battery Device' (string)
info.udi = '/org/freedesktop/Hal/devices/computer_power_supply_battery_BAT1'
(string)
info.category = 'battery' (string)
battery.type = 'primary' (string)
linux.hotplug_type = 2 (0x2) (int)
linux.subsystem = 'power_supply' (string)
info.capabilities = { 'battery' } (string list)
ndlar...@lapslave:~$ acpi -bs
Battery 0: slot empty
Battery 1: Charging, 66%, 01:11:32 until charged
While on ac, doesn't get updated neither on ac nor not.
** Affects: gnome-power-manager (Ubuntu)
Importance: Undecided
Status: New
--
battery monitoring doensn't update
https://bugs.edge.launchpad.net/bugs/329346
You received this bug notification because you are a member of Ubuntu Desktop
Bugs, which is subscribed to gnome-power-manager in ubuntu.
--