Status changed to 'Confirmed' because the bug affects multiple users.

** Changed in: upower (Ubuntu)
       Status: New => Confirmed

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to upower in Ubuntu.
https://bugs.launchpad.net/bugs/594852

Title:
  upower gives incorrect data/misleading data

Status in “upower” package in Ubuntu:
  Confirmed

Bug description:
  Binary package hint: upower

  I am using lucid.  I have a dell inspiron 6000

  upower gives data that is inconsistent with acpi.

   > acpi
  Battery 0: Charging, 27%, 01:25:50 until charged

  this agrees with the bios, so I believe it to be correct.

  
  > upower --dump
  Device: /org/freedesktop/UPower/devices/line_power_AC
    native-path:          
/sys/devices/LNXSYSTM:00/LNXSYBUS:00/ACPI0003:00/power_supply/AC
    power supply:         yes
    updated:              Tue Jun 15 22:34:20 2010 (754 seconds ago)
    has history:          no
    has statistics:       no
    line-power
      online:             yes

  Device: /org/freedesktop/UPower/devices/battery_BAT0
    native-path:          
/sys/devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0A:00/power_supply/BAT0
    vendor:               Sanyo
    model:                DELL F51267
    serial:               1410
    power supply:         yes
    updated:              Tue Jun 15 22:46:25 2010 (29 seconds ago)
    has history:          yes
    has statistics:       yes
    battery
      present:             yes
      rechargeable:        yes
      state:               charging
      energy:              14.8962 Wh
      energy-empty:        0 Wh
      energy-full:         79.92 Wh
      energy-full-design:  79.92 Wh
      energy-rate:         26.3514 W
      voltage:             11.64 V
      time to full:        2.5 hours
      percentage:          18.6389%
      capacity:            67.375%
      technology:          lithium-ion
    History (charge):
      1276638385        18.639  charging
      1276638355        18.347  charging
      1276638325        18.042  charging
    History (rate):
      1276638385        26.351  charging
      1276638355        29.393  charging
      1276638325        27.728  charging

  Daemon:
    daemon-version:  0.9.1
    can-suspend:     yes
    can-hibernate    yes
    on-battery:      no
    on-low-battery:  no
    lid-is-closed:   no
    lid-is-present:   yes

  the incorrect stat is percentage.  Note that it is 18%, i.e. different
  from what acpi reports.  this battery is an older battery and only
  holds about 65% of the design capacity when full.  So, energy-full
  seems to be wrong as well.  I don't know what capacity is, but as I
  said the last full capacity is about 2/3 of the design capacity, so it
  could be that.  In fact, 18%/67%= 27% agrees with acpi, so that is
  probably what capacity means.

  Anyways, this is causing my gnome-power-manager to report the wrong
  charge as well.

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/upower/+bug/594852/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to