Still happening for me (reporting here instead of #1083532, which seems
to be a duplicate). Here follows the dbus output when I select Page
Preview from the File menu (seems to be the most likely way to isolate
the issue so far). Error seems similar to comment #41 above.
The crux seems to be
error sender=:1.154 -> dest=:1.62
error_name=org.freedesktop.DBus.Error.UnknownMethod reply_serial=8415
string "No such interface `org.gtk.Actions' on object at path
/window/75497569"
=========[dbus output]=========
method call sender=:1.62 -> dest=:1.154 serial=8413 path=/window/75497569;
interface=org.gtk.Actions; member=SetState
string ".uno:PickList"
variant boolean false
array [
]
signal sender=:1.62 -> dest=(null destination) serial=8414
path=/com/canonical/Unity/Panel/Service;
interface=com.canonical.Unity.Panel.Service; member=EntryActivated
string ""
struct {
int32 0
int32 0
uint32 0
uint32 0
}
method call sender=:1.34 -> dest=org.ayatana.bamf serial=5682
path=/org/ayatana/bamf/matcher; interface=org.ayatana.bamf.matcher;
member=ActiveWindow
method return sender=:1.38 -> dest=:1.34 reply_serial=5682
string "/org/ayatana/bamf/window75497569"
method call sender=:1.34 -> dest=org.ayatana.bamf serial=5683
path=/org/ayatana/bamf/window75497569; interface=org.ayatana.bamf.window;
member=WindowType
method return sender=:1.38 -> dest=:1.34 reply_serial=5683
uint32 0
method call sender=:1.34 -> dest=org.ayatana.bamf serial=5684
path=/org/ayatana/bamf/window75497569; interface=org.ayatana.bamf.view;
member=Name
method return sender=:1.38 -> dest=:1.34 reply_serial=5684
string "GIC Project Report.odt - LibreOffice Writer"
error sender=:1.154 -> dest=:1.62
error_name=org.freedesktop.DBus.Error.UnknownMethod reply_serial=8413
string "No such interface `org.gtk.Actions' on object at path
/window/75497569"
method call sender=:1.62 -> dest=:1.154 serial=8415 path=/window/75497569;
interface=org.gtk.Actions; member=Activate
string ".uno:SaveAs"
array [
]
array [
]
error sender=:1.154 -> dest=:1.62
error_name=org.freedesktop.DBus.Error.UnknownMethod reply_serial=8415
string "No such interface `org.gtk.Actions' on object at path
/window/75497569"
method call sender=:1.62 -> dest=org.freedesktop.DBus serial=8416
path=/org/freedesktop/DBus; interface=org.freedesktop.DBus; member=AddMatch
string
"type='signal',interface='ca.desrt.dconf.Writer',path='/ca/desrt/dconf/Writer/user',arg0path='/com/canonical/indicator/datetime/'"
method call sender=:1.62 -> dest=org.freedesktop.DBus serial=8417
path=/org/freedesktop/DBus; interface=org.freedesktop.DBus; member=RemoveMatch
string
"type='signal',interface='ca.desrt.dconf.Writer',path='/ca/desrt/dconf/Writer/user',arg0path='/com/canonical/indicator/datetime/'"
method call sender=:1.62 -> dest=org.freedesktop.DBus serial=8418
path=/org/freedesktop/DBus; interface=org.freedesktop.DBus; member=AddMatch
string
"type='signal',interface='ca.desrt.dconf.Writer',path='/ca/desrt/dconf/Writer/user',arg0path='/com/canonical/indicator/datetime/'"
method call sender=:1.62 -> dest=org.freedesktop.DBus serial=8419
path=/org/freedesktop/DBus; interface=org.freedesktop.DBus; member=RemoveMatch
string
"type='signal',interface='ca.desrt.dconf.Writer',path='/ca/desrt/dconf/Writer/user',arg0path='/com/canonical/indicator/datetime/'"
signal sender=:1.62 -> dest=(null destination) serial=8420
path=/com/canonical/Unity/Panel/Service;
interface=com.canonical.Unity.Panel.Service; member=ReSync
string "libdatetime.so"
method call sender=:1.9 -> dest=:1.62 serial=2250
path=/com/canonical/Unity/Panel/Service;
interface=com.canonical.Unity.Panel.Service; member=SyncOne
string "libdatetime.so"
method return sender=:1.62 -> dest=:1.9 reply_serial=2250
array [
struct {
string "libdatetime.so"
string "0x83f6afc"
string "indicator-datetime"
string "13:43"
boolean true
boolean true
uint32 0
string ""
boolean false
boolean false
int32 600
}
]
=========[/dbus output]=========
The output of a working window is too long for me to capture from the
terminal window output. If it is important for comparison, and if
someone can explain how to channel dbus-message output to a temp file, I
can try that.
--
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to libreoffice in Ubuntu.
https://bugs.launchpad.net/bugs/1085169
Title:
LibreOffice Menus Stop Working even with
libreoffice>=1:3.6.2~rc2-0ubuntu4 and indicator-
appmenu>=12.10.3-0ubuntu2.1
Status in “indicator-appmenu” package in Ubuntu:
Confirmed
Status in “libreoffice” package in Ubuntu:
Incomplete
Bug description:
When using LibreOffice with Ubuntu 12.10, the menus will stop working.
That is, the menu is showing at the top of the screen, and you can
select a menu item, however nothing happens. Once the behaviour
starts, none of the menu items work, including File Exit. The only way
to get the menus to work again, is to quit LibreOffice and restart the
program.
This has been reported in Writer and Calc so far.
This happens regardless of the video driver, and on 32 or 64 bits.
This is with libreoffice version >= 1:3.6.2~rc2-0ubuntu4 and
indicator-appmenu 12.10.3-0ubuntu2.1 (currently in quantal-proposed)
ONLY. If you do not have these installed, you are hitting bug 1064962
or bug 1075263 resp..
WORKAROUND:
- Use right-click menus, toolbar buttons or keyboard shortcuts, or
- Close and reopen the document
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/indicator-appmenu/+bug/1085169/+subscriptions
--
Mailing list: https://launchpad.net/~desktop-packages
Post to : [email protected]
Unsubscribe : https://launchpad.net/~desktop-packages