Just ignore whatever Christopher is doing. People were already making
progress and preparing patches.  No need for him to step in and get
things diffused in all kinds of unproductive directions.  I rather
suggest to

1) verify if this is fixed in zesty (I will take what jeekajo is seeing for 
this ticket)
2) SRU the proposed patch as necessary
3) verify about any remaining problems and deal with them separately

** Changed in: sane-backends (Ubuntu)
     Assignee: (unassigned) => Rolf Leggewie (r0lf)

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to sane-backends in Ubuntu.
https://bugs.launchpad.net/bugs/1184699

Title:
  Canon LIDE 110 can only scan once, then I need to replug the usb cable

Status in sane-backends package in Ubuntu:
  Incomplete

Bug description:
  I have a Canon LIDE 110 scanner which works by default on ubuntu 13.04. 
  The problem is after first scan, I can not scan for second time. I need to 
reconnect the USB cable to use the scanner again.

  # TEST 1 : without reconnecting the usb cable
  francois@pc:~$ scanimage -v > test1.jpg # success
  scanimage: scanning image of size 636x885 pixels at 8 bits/pixel
  scanimage: acquiring gray frame
  scanimage: min/max graylevel value = 0/255
  scanimage: read 562860 bytes in total
  # I don't unplug plug the usb cable.
  francois@pc:~$ scanimage -v > test2.jpg # FAIL
  scanimage: no SANE devices found

  # TEST 2 : reconnect usb cable between scan attempts
  francois@pc:~$ scanimage -v > test1.jpg # success
  scanimage: scanning image of size 636x885 pixels at 8 bits/pixel
  scanimage: acquiring gray frame
  scanimage: min/max graylevel value = 0/255
  scanimage: read 562860 bytes in total
  # I unplug and replug the usb cable.
  francois@pc:~$ scanimage -v > test2.jpg # SUCCESS
  scanimage: scanning image of size 636x885 pixels at 8 bits/pixel
  scanimage: acquiring gray frame
  scanimage: min/max graylevel value = 0/255
  scanimage: read 562860 bytes in total

  francois@pc:~$ dmesg # extract
  [  829.365158] usb 3-1: USB disconnect, device number 2
  [  834.935000] usb 3-1: new high-speed USB device number 4 using xhci_hcd
  [  834.952515] usb 3-1: New USB device found, idVendor=04a9, idProduct=1909
  [  834.952519] usb 3-1: New USB device strings: Mfr=1, Product=2, 
SerialNumber=0
  [  834.952522] usb 3-1: Product: CanoScan
  [  834.952524] usb 3-1: Manufacturer: Canon
  [ 1623.738811] usb 3-1: USB disconnect, device number 4
  [ 1623.739072] xhci_hcd 0000:00:14.0: Slot 3 endpoint 6 not removed from BW 
list!
  [ 1625.528827] usb 3-1: new high-speed USB device number 5 using xhci_hcd
  [ 1625.546327] usb 3-1: New USB device found, idVendor=04a9, idProduct=1909
  [ 1625.546331] usb 3-1: New USB device strings: Mfr=1, Product=2, 
SerialNumber=0
  [ 1625.546334] usb 3-1: Product: CanoScan
  [ 1625.546336] usb 3-1: Manufacturer: Canon

  francois@pc:~$ uname -a && cat /etc/issue
  Linux pc 3.8.0-22-generic #33-Ubuntu SMP Thu May 16 15:17:14 UTC 2013 x86_64 
x86_64 x86_64 GNU/Linux
  Ubuntu 13.04 \n \l

  The problem was reported here by someone else :
  http://askubuntu.com/questions/278473/canon-lide-110-should-reconnect-
  usb-for-each-scan

  Thanks
  François

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1184699/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to