https://issues.apache.org/jira/browse/GERONIMO-3799?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Sangjin Lee closed GERONIMO-3799.
---------------------------------


> incorrect connect time computation in TimeMonitor
> -------------------------------------------------
>
>                 Key: GERONIMO-3799
>                 URL: https://issues.apache.org/jira/browse/GERONIMO-3799
>             Project: Geronimo
>          Issue Type: Bug
>      Security Level: public(Regular issues) 
>          Components: AsyncHttpClient
>    Affects Versions: 1.x
>            Reporter: Sangjin Lee
>         Attachments: GERONIMO-3799.patch
>
>
> A bug in TimeMonitor.notification() causes incorrect connect time 
> computation.  Connect start time is set only if you're opening a new 
> connection.  If a connection is reused, then connect start time is cleared 
> (i.e. reset to 0).
> In TimeMonitor, one should check to see connect start time is set before 
> recording the connect time.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to