https://issues.apache.org/activemq/browse/AMQNET-15?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

james strachan moved AMQ-994 to AMQNET-15:
------------------------------------------

        Fix Version/s: 1.0
          Component/s:     (was: NMS (C# client))
    Affects Version/s:     (was: 4.0.2)
                  Key: AMQNET-15  (was: AMQ-994)
              Project: ActiveMQ .Net  (was: ActiveMQ)

> .Net client TcpTransport does not prevent concurrent access to BinaryWriter
> ---------------------------------------------------------------------------
>
>                 Key: AMQNET-15
>                 URL: https://issues.apache.org/activemq/browse/AMQNET-15
>             Project: ActiveMQ .Net
>          Issue Type: Bug
>         Environment: Windows
>            Reporter: Rob Lugt
>             Fix For: 1.0
>
>         Attachments: patch-amq994.txt
>
>
> A client application using multiple sessions may write multiple messages 
> concurrently. The underlying TcpTransport does not synchronize access to its 
> BinaryWriter, resulting in possible data message corruption or worse.
> The TcpTransportFactory in the Java client uses a MutexTransport to protect 
> the underlying socket.  This technique would work equally well in the .Net 
> client, but I propose simply locking the writer as the TcpTransport should 
> argueably protect itselft rather than relying on the factory to provide 
> protection.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to