Can't set properties on ActiveMQBytesMessage after a reset()
------------------------------------------------------------

                 Key: AMQ-1457
                 URL: https://issues.apache.org/activemq/browse/AMQ-1457
             Project: ActiveMQ
          Issue Type: Improvement
    Affects Versions: 4.1.1, 5.0.0
            Reporter: Nic Grounds
         Attachments: propertyAfterReset.patch

Once the reset() method has been called on an ActiveMQBytesMessage object, 
properties can no longer be set.  The use case is that I need to set a property 
to represent the message length (number of bytes) but I can't determine that 
(using the getBodyLength() method) until after a call to reset().

A very crude patch is included which prevents the [unnecessary?] assumption 
that the ActiveMQBytesMessage may be uninitialized when setting an object 
property.

Note: the documentation for a JMS BytesMessage API documentation states that 
the reset() method puts the BytesMessage into read-only mode but whether this 
applies to the body only or to the body and properties is unclear.

I marked this issue as an improvement because I'm not convinced whether it is a 
bug or whether there is a another, better way to accomplish what I'm trying to 
do.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to