https://issues.apache.org/activemq/browse/AMQ-2507?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Dave Stanley updated AMQ-2507:
------------------------------
Attachment: producer_timeout_test.txt
Attaching patch with testcase that shows the problem. Cut from trunk.
> When using a producer/session with a send timeout, send() doesn't throw an
> exception if the timeout is reached.
> ---------------------------------------------------------------------------------------------------------------
>
> Key: AMQ-2507
> URL: https://issues.apache.org/activemq/browse/AMQ-2507
> Project: ActiveMQ
> Issue Type: Improvement
> Components: Broker
> Affects Versions: 5.3.0
> Environment: All platforms, 5.3.x
> Reporter: Dave Stanley
> Attachments: producer_timeout_test.txt
>
>
> In the attached testcase we set a low broker memory limit (to force a
> producer to block due to the memory usage limit being hit), and also set a
> sendtimeout on the connection to force the producer.send() to return if it
> cannot send a message within the timeout period.
> On running the test the broker sends messages until the timeout kicks in.
> Once the hits the memory limit it blocks and the producer.send() returns
> after the timeout.
> The problem is there is no way to know that the send() failed. This
> improvement is to modify the session to throw an exception of some kind when
> the sendTimeout is reached.
> I have attached the testcase without a fix as its not clear the best approach
> to fix.
> One possible solution is to modify ActiveMQSession, but need some
> clarification on whats the best JMSException to throw. It doesn't look like
> this is explicitly spelled out in the JMS Spec.
> General area is the send() method
> protected void send(ActiveMQMessageProducer producer, ActiveMQDestination
> destination, Message message, int deliveryMode, int priority, long timeToLive,
> MemoryUsage producerWindow, int sendTimeout) throws
> JMSException {
> .....
> if (sendTimeout <= 0 && !msg.isResponseRequired() &&
> !connection.isAlwaysSyncSend() && (!msg.isPersistent() ||
> connection.isUseAsyncSend() || txid != null)) {
> this.connection.asyncSendPacket(msg);
> if (producerWindow != null) {
> // Since we defer lots of the marshaling till we hit the
> // wire, this might not
> // provide and accurate size. We may change over to doing
> // more aggressive marshaling,
> // to get more accurate sizes.. this is more important
> once
> // users start using producer window
> // flow control.
> int size = msg.getSize();
> producerWindow.increaseUsage(size);
> }
> } else {
> // Handle send timeout here
> if (sendTimeout > 0) {
> Object response =
> this.connection.syncSendPacket(msg,sendTimeout);
> if(response == null) {
> LOG.debug(getSessionId() + " timeout sending message: "
> + msg);
> }
> // What jms exception is most appropriate to throw here?
> }else {
> this.connection.syncSendPacket(msg);
> }
> }
> }
--
This message is automatically generated by JIRA.
-