https://issues.apache.org/activemq/browse/AMQ-2588?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Gary Tully resolved AMQ-2588.
-----------------------------
Resolution: Fixed
fixed in r904568
> Broker async disconnect of connections while waiting for slave to connect can
> lead to hung failover transport
> -------------------------------------------------------------------------------------------------------------
>
> Key: AMQ-2588
> URL: https://issues.apache.org/activemq/browse/AMQ-2588
> Project: ActiveMQ
> Issue Type: Bug
> Components: Broker
> Affects Versions: 5.3.0
> Reporter: Gary Tully
> Assignee: Gary Tully
> Fix For: 5.4.0
>
>
> failover transport can miss an async exception or inactivity timeout
> exception while in the process of doing a reconnect and can signal
> reconnection complete in error, leading to a hang.
> Some slight changes to AMQ2183Test which demonstrated intermittent hangs made
> it reliably reproducible and lead to the diagnosis.
> Test scenario is trying to connect to a broker that is waiting for a slave to
> connect to it. so a pure master slave setup. The failover will eventually
> hang thinking it has successfully reconnected but has missed an exception.
--
This message is automatically generated by JIRA.
-