https://issues.apache.org/jira/browse/AMQCPP-328?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12970874#action_12970874
 ] 

Helen Huang commented on AMQCPP-328:
------------------------------------

I used Visual Studio 2005. Thanks!

> crash found in activemqcpp when turning broker offline
> ------------------------------------------------------
>
>                 Key: AMQCPP-328
>                 URL: https://issues.apache.org/jira/browse/AMQCPP-328
>             Project: ActiveMQ C++ Client
>          Issue Type: Bug
>          Components: CMS Impl
>    Affects Versions: 3.2.3
>         Environment: Windows xp service pack 3, ActiveMQ broker 5.3.1, apr 
> 1.4.2, apr-util 1.3.9, apr iconv 1.2.1
>            Reporter: Helen Huang
>            Assignee: Timothy Bish
>             Fix For: 3.3.0
>
>         Attachments: BrokerMonitor.zip, BrokerMonitorCrash.suo, 
> screenshot-1.jpg, test program.zip
>
>
> We found a crash in activemqcpp when we are shutting down the message broker. 
>  In the meanwhile, our application is still trying to send messages to the 
> broker, and to receive messages from it. Could you please take a look at this 
> problem? Much thanks for your help! 
> The place of the crash appears to be in TransportFilter::Fire(Exception&) on 
> line 49. The content of the address that the listener pointer is pointing to 
> seems to be corrupted/garbage. Please see the call stack in the attached 
> screen shot for details. 
> Attached please also find a test program to reproduce the problem. Step to 
> run the test program:
> (1) download and unzip test program
> (2) register GTOUD.dll
> (3) register CmsMessageHandlerCOMUD.dll
> (4) run CmsMessageHandlerCOMTest.exe
> (5) repeatedly restart activemqcpp broker. 
> (6) observe the crash

-- 
This message is automatically generated by JIRA.
-