https://issues.apache.org/jira/browse/AMQ-4352?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
SuoNayi updated AMQ-4352:
-------------------------
Attachment: AMQ4352Test.java
AMQ4352.patch
Rewrite the test case to allow graceful shutdown and try to provide a patch for
the issue.
> Expired message on the dlq miss originalExpiration property
> -----------------------------------------------------------
>
> Key: AMQ-4352
> URL: https://issues.apache.org/jira/browse/AMQ-4352
> Project: ActiveMQ
> Issue Type: Bug
> Components: JMS client
> Affects Versions: 5.x
> Reporter: SuoNayi
> Fix For: 5.9.0
>
> Attachments: AMQ4352.patch, AMQ4352Test.java
>
>
> When messages expire they are moved to the dead letter queue for
> retrospection.
> Expired messages have one originalExpiration property to indicate when it's
> expired, but we can not see the property via Web Console or using consumers
> to fetch them from the dlq.
> The unit test reproduces the problem.
--
This message is automatically generated by JIRA.