https://issues.apache.org/jira/browse/ARIES-1520?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Timothy Ward resolved ARIES-1520.
---------------------------------
    Resolution: Fixed

Fixed via commit 1737986.

> Supplying an external DataSource is not possible with the 
> EntityManagerFactoryBuilder
> -------------------------------------------------------------------------------------
>
>                 Key: ARIES-1520
>                 URL: https://issues.apache.org/jira/browse/ARIES-1520
>             Project: Aries
>          Issue Type: Bug
>          Components: JPA
>    Affects Versions: jpa-2.3.0
>            Reporter: Timothy Ward
>            Assignee: Timothy Ward
>             Fix For: jpa-2.4.0
>
>
> The Aries JPA container provides an EntityManagerFactoryBuilder service so 
> that clients can provide persistence unit configuration at runtime. 
> One of the things that clients are supposed to be able to do is to provide 
> ready configured database connections at runtime using the 
> javax.persistence.jtaDataSource and javax.persistence.nonJtaDataSource 
> properties.
> This works for EclipseLink (the JPA RI) but does not with Hibernate or 
> OpenJPA. Both Hibernate and OpenJPA see the PersistenceUnitInfo return null 
> and then fail when they find no Driver class name. The 
> EntityManagerFactoryBuilder can fix this by overriding the 
> PersistenceUnitInfo's DataSource using the supplied standard property names.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to