Duncan Grant created BROOKLYN-552:
-------------------------------------
Summary: Tomcat entity stop / start fails as entity id changes
which update run_dir but tc obviously not moved
Key: BROOKLYN-552
URL: https://issues.apache.org/jira/browse/BROOKLYN-552
Project: Brooklyn
Issue Type: Bug
Reporter: Duncan Grant
Priority: Critical
Reproduce:
Deploy tomcat with:
name: Test Tomcat
location:
centos7_gce_europe
services:
type: org.apache.brooklyn.entity.webapp.tomcat.TomcatServer
after entity is running do
br app <appid> ent <entityid> stop
br app <appid> ent <entityid> start
The isrunning check will never pass as the run_dir sensor will have upated but
obviously the directory is not moved on the vm
This is presumably a problem with all blueprints that use the standard pid
check for running???
--
This message was sent by Atlassian JIRA
(v6.4.14#64029)