Hello,

the TCK in the Cmis Workbench returns the following warnings for a type with 
versioning:

---------------------------------------------------------------
Versioning Smoke Test (ATOMPUB) (190 ms)
---------------------------------------------------------------

  WARNING: PWC does not have a value for cmis:versionSeriesCheckedOutBy! 
(VersioningSmokeTest.java:128)
    INFO: String is null!

  WARNING: PWC does not have a value for cmis:versionSeriesCheckedOutBy! 
(VersioningSmokeTest.java:128)
    INFO: String is null!


As far as I understand the CMIS specification it is not required that this 
property has any value or is this a misinterpretation?

Thank you very much in advance and best regards,
Achim