Looking at the EC2 Cloudwatch sample Michal once shared with me, I'm
still not sure how to interpret their data and how it should be modelled
in DC.
Let me copy and paste part of the XML he sent me:

<?xml version="1.0" encoding="UTF-8"?>
<metric href="http://localhost:3002/api/metrics/i-5cac1c24";
id="i-5cac1c24">
  <entity>i-5cac1c24</entity>
  <properties>
    <NetworkIn>
    <sample>
      <property name="timestamp" value="2012-07-09T12:38:00Z"/>
      <property name="unit" value="Bytes"/>
      <property name="minimum" value="42.0"/>
      <property name="maximum" value="42.0"/>
      <property name="average" value="42.0"/>
      <property name="samples" value="1.0"/>
    </sample>
    <sample>
      <property name="timestamp" value="2012-07-09T12:34:00Z"/>
      <property name="unit" value="Bytes"/>
      <property name="minimum" value="84.0"/>
      <property name="maximum" value="84.0"/>
      <property name="average" value="84.0"/>
      <property name="samples" value="1.0"/>
    </sample>
    <sample>
...

What I observe is:
1. The 'samples' value is always 1. I suppose that's why a sample's min,
max and average are the same. In what case would samples not be 1?
2. Even though the 'samples' value is 1, clearly it returns multiple
samples (=measurements?) over a period (every 6 min. judging from the
timestamp).

The only useful data I get is the 42 and 84 and their timestamps. FGCP
returns that data too, it just doesn't call them average, min and max.
Do we need to include it three times in the DC API?

        <sample timestamp="..." count="..." unit="...">
          <entry name="average" value="42.0"/>
<!--
          <entry name="minimum" value="42.0"/>
          <entry name="maximum" value="42.0"/>
-->
        </sample>

Regards,
Dies Koper


> -----Original Message-----
> From: David Lutterkort [mailto:[email protected]]
> Sent: Tuesday, 28 August 2012 10:32 AM
> To: [email protected]
> Subject: RE: normalised metric names?
> 
> On Fri, 2012-08-24 at 16:46 +1000, Koper, Dies wrote:
> > Hi David,
> >
> > > normalized name should not contain a unit ("nicInputByte"), and
I'd
> > > prefer if it was underscored, but whether we call it network_in or
> > > nic_input doesn't make a difference to me.
> >
> > I've made a new list (below).
> > I'm suggesting nic instead of network for consistency with cpu (vs.
> > compute).
> > I wonder if that will turn out to be the better choice if providers
> > start returning samples per nic (when a server has several), or not
:)
> >
> > EC2 "provider_probe"        FGCP "provider_probe"
Normalised
> > "probe"
> > CPUUtilization              cpuUtilization
cpu_utilization
> >
> > NetworkIn           nicInputByte                    nic_in
> > NetworkOut          nicOutputByte                   nic_out
> > -                   nicInputPacket                  -
> > -                   nicOutputPacket         -
> >
> > DiskReadOps         diskReadRequestCount            disk_read_ops
> > DiskWriteOps                diskWriteRequestCount
disk_write_ops
> > DiskReadBytes               -                               -
> > DiskWriteBytes              -                               -
> > -                   diskReadSector                  -
> > -                   diskWriteSector                 -
> 
> Those names work for me.
> 
> > > seems clearer; this would indicate that we took a sample at
> > @timestamp,
> > > consisting of @count measurements, and the values are reported in
> > @unit.
> > > The body of <sample/> only contains the statistics for that one
> > sample.
> > >
> > > What isn't clear to me is how we can talk about taking a sample at
a
> > > certain time when that sample consists of multiple measurements -
> > > shouldn't that sample then have an underlying time period (from
time X
> > > to time Y, we looked N times, and here are aggregate stats of what
we
> > > saw ?)
> >
> > FGCP doesn't return "average", min and max for metrics. It just
returns
> > a number for each.
> > I assumed each sample returned subtotals since the previous
measurement.
> > Except for cpu utilization, not sure how that's determined.
> 
> What EC2 does, is that it takes a number N of samples, and then tells
> you N and aggregate statistics for those N. If FGCP returns
measurements
> directly, we can just indicate that by saying we took 1 measurement
and
> return the value as 'average' (or 'max' or 'min' ;)
> 
> David
> 
> 


Reply via email to