Looking at the EC2 Cloudwatch sample Michal once shared with me, I'm still not sure how to interpret their data and how it should be modelled in DC. Let me copy and paste part of the XML he sent me:
<?xml version="1.0" encoding="UTF-8"?> <metric href="http://localhost:3002/api/metrics/i-5cac1c24" id="i-5cac1c24"> <entity>i-5cac1c24</entity> <properties> <NetworkIn> <sample> <property name="timestamp" value="2012-07-09T12:38:00Z"/> <property name="unit" value="Bytes"/> <property name="minimum" value="42.0"/> <property name="maximum" value="42.0"/> <property name="average" value="42.0"/> <property name="samples" value="1.0"/> </sample> <sample> <property name="timestamp" value="2012-07-09T12:34:00Z"/> <property name="unit" value="Bytes"/> <property name="minimum" value="84.0"/> <property name="maximum" value="84.0"/> <property name="average" value="84.0"/> <property name="samples" value="1.0"/> </sample> <sample> ... What I observe is: 1. The 'samples' value is always 1. I suppose that's why a sample's min, max and average are the same. In what case would samples not be 1? 2. Even though the 'samples' value is 1, clearly it returns multiple samples (=measurements?) over a period (every 6 min. judging from the timestamp). The only useful data I get is the 42 and 84 and their timestamps. FGCP returns that data too, it just doesn't call them average, min and max. Do we need to include it three times in the DC API? <sample timestamp="..." count="..." unit="..."> <entry name="average" value="42.0"/> <!-- <entry name="minimum" value="42.0"/> <entry name="maximum" value="42.0"/> --> </sample> Regards, Dies Koper > -----Original Message----- > From: David Lutterkort [mailto:[email protected]] > Sent: Tuesday, 28 August 2012 10:32 AM > To: [email protected] > Subject: RE: normalised metric names? > > On Fri, 2012-08-24 at 16:46 +1000, Koper, Dies wrote: > > Hi David, > > > > > normalized name should not contain a unit ("nicInputByte"), and I'd > > > prefer if it was underscored, but whether we call it network_in or > > > nic_input doesn't make a difference to me. > > > > I've made a new list (below). > > I'm suggesting nic instead of network for consistency with cpu (vs. > > compute). > > I wonder if that will turn out to be the better choice if providers > > start returning samples per nic (when a server has several), or not :) > > > > EC2 "provider_probe" FGCP "provider_probe" Normalised > > "probe" > > CPUUtilization cpuUtilization cpu_utilization > > > > NetworkIn nicInputByte nic_in > > NetworkOut nicOutputByte nic_out > > - nicInputPacket - > > - nicOutputPacket - > > > > DiskReadOps diskReadRequestCount disk_read_ops > > DiskWriteOps diskWriteRequestCount disk_write_ops > > DiskReadBytes - - > > DiskWriteBytes - - > > - diskReadSector - > > - diskWriteSector - > > Those names work for me. > > > > seems clearer; this would indicate that we took a sample at > > @timestamp, > > > consisting of @count measurements, and the values are reported in > > @unit. > > > The body of <sample/> only contains the statistics for that one > > sample. > > > > > > What isn't clear to me is how we can talk about taking a sample at a > > > certain time when that sample consists of multiple measurements - > > > shouldn't that sample then have an underlying time period (from time X > > > to time Y, we looked N times, and here are aggregate stats of what we > > > saw ?) > > > > FGCP doesn't return "average", min and max for metrics. It just returns > > a number for each. > > I assumed each sample returned subtotals since the previous measurement. > > Except for cpu utilization, not sure how that's determined. > > What EC2 does, is that it takes a number N of samples, and then tells > you N and aggregate statistics for those N. If FGCP returns measurements > directly, we can just indicate that by saying we took 1 measurement and > return the value as 'average' (or 'max' or 'min' ;) > > David > >