As the code has changed the max wait time to 1000ms, the comment should
be changed accordingly.

Fixes: 64f1c8539c8c ("net/ixgbe: wait longer for link after fiber MAC setup")
Cc: [email protected]
Cc: [email protected]

Signed-off-by: Xiaolong Ye <[email protected]>
---
 drivers/net/ixgbe/base/ixgbe_common.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/net/ixgbe/base/ixgbe_common.c 
b/drivers/net/ixgbe/base/ixgbe_common.c
index 21f973e5e..fb50719fb 100644
--- a/drivers/net/ixgbe/base/ixgbe_common.c
+++ b/drivers/net/ixgbe/base/ixgbe_common.c
@@ -5259,7 +5259,7 @@ s32 ixgbe_setup_mac_link_multispeed_fiber(struct ixgbe_hw 
*hw,
                ixgbe_flap_tx_laser(hw);
 
                /* Wait for the controller to acquire link.  Per IEEE 802.3ap,
-                * Section 73.10.2, we may have to wait up to 500ms if KR is
+                * Section 73.10.2, we may have to wait up to 1000ms if KR is
                 * attempted.  82599 uses the same timing for 10g SFI.
                 */
                for (i = 0; i < 10; i++) {
-- 
2.17.1