On Wed, Apr 8, 2020 at 12:48 AM Thomas Monjalon <[email protected]> wrote: > > When a log type is registered, the level can be picked > by matching saved options. > The check of fnmatch globbing result was reversed. > > The same bug was already fixed in a similar function. > This one is acting in log type register function. > > Note: this function rte_log_register_type_and_pick_level() > is not used a lot and could be merged with rte_log_register().
Same fix as a patch I sent quite some time ago and left behind.. https://patchwork.dpdk.org/patch/57742/ I left it in a series I wanted to work on later... Anyway, this fix is needed. I suppose we are missing a unit test too. -- David Marchand