From: Tonghao Zhang <xiangxia.m....@gmail.com> If user don't set the dv_xmeta_en to 1 or 2, in the flow_dv_convert_action_set_meta function: * flow_dv_get_metadata_reg may return the REG_NONE, when MLX5_METADATA_FDB enabled for metadata set action. * reg_to_field(REG_NONE) return MLX5_MODI_OUT_NONE which is invalid.
The rdma-core calltrace: dr_action_create_modify_action dr_actions_convert_modify_header dr_action_modify_sw_to_hw dr_action_modify_sw_to_hw_set dr_ste_get_modify_hdr_hw_field sw_field [MLX5_MODI_OUT_NONE 4095] should not > ste_ctx->modify_hdr_field_arr_sz [92] As doc[1] says: | dv_xmeta_en 0, this is default value, defines the legacy mode, | the MARK and META related actions and items operate only within | NIC Tx and NIC Rx steering domains, no MARK and META information | crosses the domain boundaries. This patch add check for that case to warn that not supported. [1] - http://doc.dpdk.org/guides-20.02/nics/mlx5.html Signed-off-by: Tonghao Zhang <xiangxia.m....@gmail.com> --- drivers/net/mlx5/mlx5_flow_dv.c | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/drivers/net/mlx5/mlx5_flow_dv.c b/drivers/net/mlx5/mlx5_flow_dv.c index e4818319507c..dfcaf90eda11 100644 --- a/drivers/net/mlx5/mlx5_flow_dv.c +++ b/drivers/net/mlx5/mlx5_flow_dv.c @@ -1251,6 +1251,12 @@ flow_dv_convert_action_set_meta if (reg < 0) return reg; + + if (reg == REG_NONE) + return rte_flow_error_set(error, ENOTSUP, + RTE_FLOW_ERROR_TYPE_ITEM, + NULL, "unavailable " + "metadata register"); /* * In datapath code there is no endianness * coversions for perfromance reasons, all -- 2.26.1