> -----Original Message----- > From: Kumar, Rajesh3 <[email protected]> > Sent: 15 September 2026 18:32 > To: Mandal, Anurag <[email protected]> > Cc: [email protected] > Subject: Re: [PATCH v3] net/iavf: support reading PHC time > > The new iavf_timesync_read_time() callback converts every error returned by > iavf_phc_get_time() to -EIO. The underlying AdminQ path can return more > specific errors, including -ENOTSUP and -EINVAL, so this prevents callers from > distinguishing an unsupported operation from an actual I/O failure. > > Could the original error be propagated instead? > > ret = iavf_phc_get_time(adapter, &time); > if (ret != 0) > return ret;
Sure. Let me try the same. Thank you. Regards, Anurag M