https://issues.apache.org/jira/browse/FELIX-885?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Felix Meschberger resolved FELIX-885.
-------------------------------------
Resolution: Fixed
The problem is the ConfigManager.getConfiguration(ConfigurationAdming, String,
String) method which created a new factory configuration instance whenever
factoryPid was not null. This is wrong, since a new instance should only be
created if the pid is null or the placeholder pid used to create a temporary
configuration instance used to build configuration form.
Applied fix in Rev. 735450 and deployed SNAPSHOT version
1.2.3-20090118.131353-3.
Keeping this issue open until I get feedback from the reporting user.
> Saving a factory configuraiton instance creates a new instance instead of
> updating the old instance
> ---------------------------------------------------------------------------------------------------
>
> Key: FELIX-885
> URL: https://issues.apache.org/jira/browse/FELIX-885
> Project: Felix
> Issue Type: Bug
> Components: Configuration Admin
> Affects Versions: webconsole-1.2.2
> Reporter: Felix Meschberger
> Assignee: Felix Meschberger
> Fix For: webconsole-1.2.4
>
>
> When modifying and saving an existing factory configuration instance in the
> web console, a new instance is created with the new configuraiton values
> instead of updating the actual existing configuraiton instance with the new
> values.
> This behaviour has also been reported on the Sling Developers list [1]
> [1] http://markmail.org/message/4zelcrodtfisqa5m
--
This message is automatically generated by JIRA.
-