Kostas Kloudas created FLINK-4651:
-------------------------------------
Summary: Re-register processing time timers at the WindowOperator
upon recovery.
Key: FLINK-4651
URL: https://issues.apache.org/jira/browse/FLINK-4651
Project: Flink
Issue Type: Bug
Components: Windowing Operators
Reporter: Kostas Kloudas
Assignee: Kostas Kloudas
Fix For: 1.1.3
Currently the {{{WindowOperator}}} checkpoints the processing time timers, but
upon recovery it does not re-registers them with the {{{TimeServiceProvider}}}.
To actually reprocess them it relies on another element that will come and
register a new timer for a future point in time. Although this is a realistic
assumption in long running jobs, we can remove this assumption by
re-registering the restored timers with the {{{TimeServiceProvider}}} in the
{{{open()}}} method of the {{{WindowOperator}}}.
--