Thomas Weise created FLINK-14107:
------------------------------------

             Summary: Kinesis consumer record emitter may deadlock under event 
time alignment
                 Key: FLINK-14107
                 URL: https://issues.apache.org/jira/browse/FLINK-14107
             Project: Flink
          Issue Type: Bug
          Components: Connectors / Kinesis
    Affects Versions: 1.9.0, 1.8.2
            Reporter: Thomas Weise
            Assignee: Thomas Weise


When the emitter reaches the max timestamp for the current queue, it stops 
emitting and waits for the max timestamp to advance. Since it simultaneously 
selects the next queue as the new "minimum" queue, it may deadlock if the 
previous min queue represents the new global lower bound after the max 
timestamp advanced. This occurs very infrequently and we were finally able to 
reproduce.



--
This message was sent by Atlassian Jira
(v8.3.2#803003)

Reply via email to