Colin Smetz created FLINK-28861:
-----------------------------------
Summary: Cannot resume from savepoint when using
fromChangelogStream in upsert mode
Key: FLINK-28861
URL: https://issues.apache.org/jira/browse/FLINK-28861
Project: Flink
Issue Type: Bug
Components: Runtime / Checkpointing
Affects Versions: 1.15.1
Reporter: Colin Smetz
I want to use the savepoint mechanism to move existing jobs from one version of
Flink to another, by:
# Stopping a job with a savepoint
# Creating a new job from the savepoint, on the new version.
In Flink 1.15.1, it fails, even when going from 1.15.1 to 1.15.1 I get this
error, meaning that it could not map the state from the previous job to the new
one because of one operator:
{{Failed to rollback to checkpoint/savepoint
hdfs://hdfs-name:8020/flink-savepoints/savepoint-046708-238e921f5e78. Cannot
map checkpoint/savepoint state for operator d14a399e92154660771a806b90515d4c to
the new program, because the operator is not available in the new program.}}
After investigation, the problematic operator corresponds to a
{{ChangelogNormalize}} operator, that I do not explicitly create. It is
generated because I use [{{tableEnv.fromChangelogStream(stream, schema,
ChangelogMode.upsert())}}|https://nightlies.apache.org/flink/flink-docs-release-1.15/api/java/org/apache/flink/table/api/bridge/java/StreamTableEnvironment.html#fromChangelogStream-org.apache.flink.streaming.api.datastream.DataStream-org.apache.flink.table.api.Schema-org.apache.flink.table.connector.ChangelogMode-]
(the upsert mode is important, other modes do not fail). The table created is
passed to an SQL query using the SQL API, which generates something like:
{{ChangelogNormalize[8] -> Calc[9] -> TableToDataSteam ->
[my_sql_transformation] -> [my_sink]}}
In previous versions of Flink it seems this operator was always given the same
uid so the state could match when starting from the savepoint. In Flink 1.15.1,
I see that a different uid is generated every time. I could not find a reliable
way to set that uid manually. The only way I found was by going backwards from
the transformation:
{{dataStream.getTransformation().getInputs().get(0).getInputs().get(0).getInputs().get(0).setUid("the_user_defined_id");}}
--
This message was sent by Atlassian Jira
(v8.20.10#820010)