Hey Yun,

I wonder whether we need to add a new option when registering timers. Won't
it be sufficient to flush all pending timers on termination but not allow
new ones to be registered?

-Max

On Wed, Nov 2, 2022 at 11:20 AM Yun Gao <yungao...@aliyun.com.invalid>
wrote:

> Hi everyone,
> I would like to open a discussion[1] on how to
> properly handle the processing timers on job
> termination.
> Currently all the processing timers would be
> ignored on job termination. This behavior is
> not suitable for some cases like WindowOperator.
> Thus we'd like to provide more options for how
> to deal with the pending times on job termination,
> and provide correct semantics on bounded stream
> for these scenarios. The FLIP is based on the previous
> discussion with Piotr and Divye in [2].
> [1]
> https://cwiki.apache.org/confluence/display/FLINK/FLIP-269%3A+Properly+Handling+the+Processing+Timers+on+Job+Termination
> <
> https://cwiki.apache.org/confluence/display/FLINK/FLIP-269%3A+Properly+Handling+the+Processing+Timers+on+Job+Termination
> >
> [2] https://issues.apache.org/jira/browse/FLINK-18647 <
> https://issues.apache.org/jira/browse/FLINK-18647 >
>