Zhongmin Qiao created FLINK-36347:
-------------------------------------
Summary: Using the offset obtained after a query transaction as a
high watermark cannot ensure exactly-once semantics.
Key: FLINK-36347
URL: https://issues.apache.org/jira/browse/FLINK-36347
Project: Flink
Issue Type: Bug
Components: Flink CDC
Affects Versions: cdc-3.2.0
Reporter: Zhongmin Qiao
Fix For: cdc-3.2.1
Attachments: image-2024-09-22-16-51-09-930.png
!image-2024-09-22-16-51-09-930.png!
Using the offset obtained after a query transaction as a high watermark cannot
ensure exactly-once semantics because "show master status" and the query action
are not in the same transaction. There may be data inserted between the query
action and the retrieval of the high watermark. As a result, these data will be
lost since we only deliver data after the high watermark during the binlog
phase.
--