Miroslav Holubec created FLUME-2593:
---------------------------------------
Summary: ResettableFileInputStream returns negate values from
read() method
Key: FLUME-2593
URL: https://issues.apache.org/jira/browse/FLUME-2593
Project: Flume
Issue Type: Bug
Affects Versions: v1.5.2
Reporter: Miroslav Holubec
Priority: Minor
the int value returned from the method should be in range 0-255 for a byte
read, or -1 when EOF was reached, as described in InputStream class javadoc.
Fix is to change the line in read() method:
{noformat}
return byteBuf[0];
{noformat}
to
{noformat}
return byteBuf[0] && 0xFF;
{noformat}
--
This message was sent by Atlassian JIRA