seongsu shin created HTTPCORE-804:
-------------------------------------
Summary: H2Config.copy() does not copy maxContinuations
Key: HTTPCORE-804
URL: https://issues.apache.org/jira/browse/HTTPCORE-804
Project: HttpComponents HttpCore
Issue Type: Bug
Reporter: seongsu shin
H2Config.copy(config) leaves out maxContinuations, so the copied builder goes
back to the default of 100.
{code:java}
H2Config config = H2Config.custom().setMaxContinuations(5).build();
H2Config.copy(config).build().getMaxContinuations(); // 100, expected 5
{code}
I ran into this through WebSocketH2ServerBootstrap in httpclient5-websocket.
When push is enabled, setH2Config() does
{{H2Config.copy(h2Config).setPushEnabled(false).build()}}. Push is on by
default, so a server set up with
{{H2Config.custom().setMaxContinuations(2).build()}} actually runs with a limit
of 100.
To check it end to end I started a WebSocketH2ServerBootstrap server
(FORCE_HTTP_2, maxContinuations=2) and sent one HEADERS frame followed by 14
CONTINUATION frames from a plain socket:
||H2Config passed to setH2Config()||result||
|pushEnabled=true (goes through copy())|header block accepted, server responds
on stream 1|
|pushEnabled=false (used as is)|GOAWAY ENHANCE_YOUR_CALM "Excessive number of
continuation frames"|
After adding {{.setMaxContinuations(config.getMaxContinuations())}} to copy(),
both cases get the GOAWAY.
Tested with core master (2f7e88e88) and client master (724cf0044).
The same line is also in PR #695 (ORIGIN frame), but that one is a larger
change. I can send a small PR with a test for just this if that helps.
--
This message was sent by Atlassian Jira