On Fri, Apr 26, 2002 at 11:13:55AM -0500, Rose, Billy wrote: > As per a previous email, I was going to create a new MPM that had a > "dispatcher" sitting between the listener and the workers that would handle > all of the queueing problems via signaling. I will have to defer that > project at present due to workload at my job. However, in the current > discussion on the worker MPM, how about having an overflow buffer that the > listener stuffs connections into. Once threads wake up (or are created), > they check that buffer first for any other work and before sleeping. A mutex > would regulate access to the queue. Comments???
That is what we have now, and having the "overflow" portion is the essense of our problem. -aaron