Vladimir Steshin created IGNITE-13015:
-----------------------------------------
Summary: Use nono time instead of currentMills() in node failure
ddetection.
Key: IGNITE-13015
URL: https://issues.apache.org/jira/browse/IGNITE-13015
Project: Ignite
Issue Type: Improvement
Reporter: Vladimir Steshin
Assignee: Vladimir Steshin
Make sure in node failure detection not used:
{code:java}
System.currentTimeMillis()
and
IgniteUtils.currentTimeMillis()
{code}
Disadventages:
1) Current system time has no quarantine of strict forward movement.
System time can be adjusted, synchronized by NTP as example. This can lead to
incorrect and negative delays.
2) IgniteUtils.currentTimeMillis() is granulated by 10ms
--
This message was sent by Atlassian Jira
(v8.3.4#803005)