Sure. I’ll investigate it.

Thanks,
Jinrui

From: Xiangdong Huang <[email protected]>
Sent: Tuesday, July 2, 2019 7:16 PM
To: [email protected]; Jinrui Zhang <[email protected]>
Subject: Re: [jira] [Created] (IOTDB-124) Lost timeseries info after I restart 
IoTDB

Hi,

@Jinrui, can you pay some attention to this issue?

Best,
-----------------------------------
Xiangdong Huang
School of Software, Tsinghua University

 黄向东
清华大学 软件学院


FengQingxin (JIRA) <[email protected]<mailto:[email protected]>> 于2019年7月2日周二 
下午3:00写道:
FengQingxin created IOTDB-124:
---------------------------------

             Summary: Lost timeseries info after I restart IoTDB
                 Key: IOTDB-124
                 URL: 
https://issues.apache.org/jira/browse/IOTDB-124<https://nam06.safelinks.protection.outlook.com/?url=https%3A%2F%2Fissues.apache.org%2Fjira%2Fbrowse%2FIOTDB-124&data=02%7C01%7CJinrui.Zhang%40microsoft.com%7C6742ca3901d94c02e7ed08d6fedeb122%7C72f988bf86f141af91ab2d7cd011db47%7C1%7C1%7C636976629748685609&sdata=h6iNNmiN5RFrhJLF9fuPZ2T9Xco0V%2Fy50XI5Hv4pkK0%3D&reserved=0>
             Project: Apache IoTDB
          Issue Type: Bug
            Reporter: FengQingxin
         Attachments: image-2019-07-02-14-54-38-359.png, 
image-2019-07-02-14-55-14-334.png

When I restart my IoTDB service, I got this error message :

2019-07-02 14:44:30,283 [main] ERROR org.apache.iotdb.db.metadata.MManager:150 
- Cannot read MGraph from file, using an empty new one

After that , I got a empty IoTDB , no timeseries info can be selected. but I 
can find Tsfile in folder 'data'. like this:

!image-2019-07-02-14-54-38-359.png!

Error:

!image-2019-07-02-14-55-14-334.png!



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to