Hi

The fix in jmeterw.cmd fix both options

FYI

On Thu, Sep 6, 2018 at 12:11 PM, Antonio Gomes Rodrigues <[email protected]>
wrote:

> If a use jmeterw.cmd without modification, it's doesn't works
>
> jmeter.bat wotks fine
>
> If I change "Apache JMeter" to "Apache_JMeter" in jmeterw.cmd, now
> jmeterw.cmd works
>
> Antonio
>
> Le jeu. 6 sept. 2018 à 10:28, Felix Schumacher <
> [email protected]> a écrit :
>
> > Am 06.09.2018 10:05, schrieb Antonio Gomes Rodrigues:
> > > Hi,
> > >
> > > Tested with apache-jmeter-r1840164 in a windows 10 and it's works fine
> > >
> > > Can you give us more information (windows release...)
> >
> > I tested it here on windows 7 and it gave the same error message. It
> > seems the cmd shell doesn't like a variable with spaces inside quotes.
> > My workaround was to change "Apache JMeter" to "Apache_JMeter".
> >
> > Could both of you test if after those changes (in jmeter.cmd and
> > jmeterw.cmd) the start script still work?
> >
> > Thanks,
> >   Felix (who doesn't like windows batch scripts, especially their
> > handling of spaces and quotes :)
> >
> > >
> > > Le jeu. 6 sept. 2018 à 07:59, Jmeter Tea <[email protected]> a écrit
> > > :
> > >
> > >>  Hello,
> > >>
> > >> jmeter.bat ot jmeterw stop working on nightly build, error in console
> > >> :
> > >> JMeter"" was unexpected at this time.
> > >>
> > >> I suspect the following change is relevant:
> > >> if "%JM_START%" == "start" (
> > >>     set JM_START=start "Apache JMeter"
> > >> )
> > >>
> > >> FYI
> > >>
> >
>

Reply via email to