Hi The fix in jmeterw.cmd fix both options
FYI On Thu, Sep 6, 2018 at 12:11 PM, Antonio Gomes Rodrigues <[email protected]> wrote: > If a use jmeterw.cmd without modification, it's doesn't works > > jmeter.bat wotks fine > > If I change "Apache JMeter" to "Apache_JMeter" in jmeterw.cmd, now > jmeterw.cmd works > > Antonio > > Le jeu. 6 sept. 2018 à 10:28, Felix Schumacher < > [email protected]> a écrit : > > > Am 06.09.2018 10:05, schrieb Antonio Gomes Rodrigues: > > > Hi, > > > > > > Tested with apache-jmeter-r1840164 in a windows 10 and it's works fine > > > > > > Can you give us more information (windows release...) > > > > I tested it here on windows 7 and it gave the same error message. It > > seems the cmd shell doesn't like a variable with spaces inside quotes. > > My workaround was to change "Apache JMeter" to "Apache_JMeter". > > > > Could both of you test if after those changes (in jmeter.cmd and > > jmeterw.cmd) the start script still work? > > > > Thanks, > > Felix (who doesn't like windows batch scripts, especially their > > handling of spaces and quotes :) > > > > > > > > Le jeu. 6 sept. 2018 à 07:59, Jmeter Tea <[email protected]> a écrit > > > : > > > > > >> Hello, > > >> > > >> jmeter.bat ot jmeterw stop working on nightly build, error in console > > >> : > > >> JMeter"" was unexpected at this time. > > >> > > >> I suspect the following change is relevant: > > >> if "%JM_START%" == "start" ( > > >> set JM_START=start "Apache JMeter" > > >> ) > > >> > > >> FYI > > >> > > >
