Sanjana Kaundinya created KAFKA-10021:
-----------------------------------------
Summary: When reading to the end of the config log, check if
fetch.max.wait.ms is greater than worker.sync.timeout.ms
Key: KAFKA-10021
URL: https://issues.apache.org/jira/browse/KAFKA-10021
Project: Kafka
Issue Type: Bug
Components: KafkaConnect
Reporter: Sanjana Kaundinya
Currently in the Connect code in DistributedHerder.java, we see the following
piece of code
{{ if (!canReadConfigs && !readConfigToEnd(workerSyncTimeoutMs))
return; // Safe to return and tick immediately because
readConfigToEnd will do the backoff for us}}
where the workerSyncTimeoutMs passed in is the timeout given to read to the end
of the config log. This is a bug as we should check if fetch.wait.max.ms is
greater than worker.sync.timeout.ms and if it is, use worker.sync.timeout.ms as
the fetch.wait.max.ms. A better fix would be to use the AdminClient to read to
the end of the log, but at a minimum we should check the configs.
--
This message was sent by Atlassian Jira
(v8.3.4#803005)