Thanks all for the clarification.

Regards,

Fang Wang
Solution Architect, Conversational Speech Solutions
IBM Certified IT Specialist
IBM Software Services for Websphere
e-mail: [email protected]
********************************************
Cell: (214)394-4757 **NEW NUMBER**
********************************************
______________________________
Certified Nuance Technical Associate
Nuance Enterprise Technologies




From:
"Rees, Kevron" <[email protected]>
To:
"Hanchett, Paul" <[email protected]>, 
Cc:
Fang Wang/West Palm Beach/IBM@IBMUS, "[email protected]" 
<[email protected]>, "[email protected]" <[email protected]>
Date:
01/31/2014 11:41 AM
Subject:
Re: [Dev] mismatch in vehicle data from AMB DBus plugin API and the HVAC 
web application?



In addition to what Paul said, the web api has a "zone" attribute that
should correspond with the DBus API zone.  You can find out which zone
a given objectName is in with the listZones call:

https://review.tizen.org/gerrit/gitweb?p=profile/ivi/wrt-plugins-ivi.git;a=blob;f=src/Vehicle/Vehicle.idl;h=324b09a996c0da0c7d794bdbd803702bf4320f09;hb=refs/heads/tizen#l122


-Kevron

On Fri, Jan 31, 2014 at 8:23 AM, Hanchett, Paul
<[email protected]> wrote:
> Fang--
>
> AMB defines a base set of property types (like the SeatHeater setting 
you
> mention). At initialization time, a plugin instantiates storage for the
> property and assigns it to a Zone (names like Zone::None, Zone:Front,
> Zone:Left, Zone::Right, Zone::LeftFront which is a sort of logical OR
> between Zone::Front and Zone::Left-- Look for the Zone class...)
>
> So, in the case you mention a plugin would declare that there's a 
SeatHeater
> in Zone::LeftFront and another in Zone::RightFront.
>
> Paul
>
>
>
> Paul Hanchett
> -------------------
> Infotainment Engineer
> MSX on behalf of Jaguar Land Rover
> One World Trade Center, 121 Southwest Salmon Street, 11th Floor, 
Portland,
> Oregon, 97204
>
> Email: [email protected]
> -------------------
>
> Business Details:
> Jaguar Land Rover Limited
> Registered Office: Abbey Road, Whitley, Coventry CV3 4LF
> Registered in England No: 1672070
>
>
> On Fri, Jan 31, 2014 at 3:43 AM, Fang Wang <[email protected]> wrote:
>>
>> Hi,
>>
>> I looked through the vehicle data in the AMB DBus API. There are some
>> mismatches between the data at DBus layer and the representation at the 
web
>> application. For example, for HVAC, the web app shows seat heater for 
left
>> side and right side. But the api layer only shows one SeatHeater 
property.
>> Similarly for TargetTemperature. How would these be mapped out? For the 
Auto
>> and Max buttons on HVAC web application, my understanding is that the 
logic
>> is in the web application to turn on a few other properties based on
>> different scenarios. But not sure how these two sides properties at 
HVAC web
>> app mapped to the single properties at DBus layer. Did I miss anything. 
I
>> did see the latest change to move defrost property in to windows object 
so
>> can specify the rows for the defrost button, which would distinguish 
the
>> front and back defrost? thanks.
>>
>>
>> Regards,
>>
>> Fang Wang
>> Solution Architect, Conversational Speech Solutions
>> IBM Certified IT Specialist
>> IBM Software Services for Websphere
>> e-mail: [email protected]
>> ********************************************
>> Cell: (214)394-4757 **NEW NUMBER**
>> ********************************************
>> ______________________________
>> Certified Nuance Technical Associate
>> Nuance Enterprise Technologies
>>
>> _______________________________________________
>> Dev mailing list
>> [email protected]
>> https://lists.tizen.org/listinfo/dev
>>
>
>
> _______________________________________________
> IVI mailing list
> [email protected]
> https://lists.tizen.org/listinfo/ivi
>



_______________________________________________
Dev mailing list
[email protected]
https://lists.tizen.org/listinfo/dev

Reply via email to