On Sun, Mar 31, 2013 at 6:23 PM, Robert Muir <[email protected]> wrote:
> hmm there goes that theory. Maybe its just a leftover process that didn't
> get killed from a previous smoketester: I think to be safe the python code
> should always terminate the server it starts with 'kill -9' and nothing
> else!

It does kill the server ... but there was a bug in that logic such
that if the 30 minute startup wait elapsed it failed to kill it.

Which is curious ... it seems to mean that the server took 30 minutes,
didn't seem to start, but did in fact start (after 30 minutes) and
bind to the port.

But this could just be a stupid bug in smokeTester.  All it looks for
is "Started [email protected]:8983" in the server's stderr
output.  Maybe this is too brittle?

Mike McCandless

http://blog.mikemccandless.com

---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]