https://issues.apache.org/jira/browse/LUCENENET-593?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Shad Storhaug resolved LUCENENET-593.
-------------------------------------
Resolution: Fixed
Assignee: Shad Storhaug
Fix Version/s: Lucene.Net 4.8.0
Resolved with these commits:
*
https://github.com/apache/lucenenet/commit/c14c27e7696cf88d628dae83b5190d8c87e9fac8
*
https://github.com/apache/lucenenet/commit/f486e5c421f2be952ff6805b8b0dfa457513e5a1
> NullReferenceException in Linux
> -------------------------------
>
> Key: LUCENENET-593
> URL: https://issues.apache.org/jira/browse/LUCENENET-593
> Project: Lucene.Net
> Issue Type: Bug
> Components: Lucene.Net Core
> Affects Versions: Lucene.Net 4.8.0, Lucene.Net 5.0 PCL
> Environment: Linux (ubuntu 64 bit, maybe all linux variants)
> Reporter: Warren Falk
> Assignee: Shad Storhaug
> Fix For: Lucene.Net 4.8.0
>
>
> A NullReferenceException on any attempt to query in Linux (ubuntu x64 in my
> tests)
> I was able to track this down to the following line in Constants.cs
> {{public static readonly string OS_ARCH =
> GetEnvironmentVariable("PROCESSOR_ARCHITECTURE", "x86");}}
> Sure enough, PROCESSOR_ARCHITECTURE is not set by default in ubuntu server
> x64 and when I set it, there is no failure.
> I would fix this, but I'm not sure what this value is used for, so I am not
> sure what the appropriate behavior should be. Should we try to find the
> correct architecture here? And what is the correct string, "amd64", "x64",
> "x86_64"? Or do we really just want to know the value of that if it is
> actually not set, should we leave it blank? The issue is that the InfoWriter
> can't write a null, but it could write an empty string.
> I'll submit a pull request if anyone can tell me what correct behavior should
> be.
--
This message was sent by Atlassian JIRA
(v6.4.14#64029)