https://issues.apache.org/jira/browse/MESOS-1031?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13921552#comment-13921552
 ] 

Niklas Quarfot Nielsen commented on MESOS-1031:
-----------------------------------------------

In case of shutdown(), there will be an upper limit of 5 seconds. But 
otherwise, you are right. An enhancement would perhaps be to be able to specify 
it in the FrameworkInfo/TaskInfo?

> Command executor should support signal escalation.
> --------------------------------------------------
>
>                 Key: MESOS-1031
>                 URL: https://issues.apache.org/jira/browse/MESOS-1031
>             Project: Mesos
>          Issue Type: Improvement
>          Components: slave
>            Reporter: Niklas Quarfot Nielsen
>
> To make command executor shutdown more graceful, the sequence could allow 
> signal escalation with initial SIGTERM followed by SIGKILL after an 
> appropriate timeout. This became apparent when we where using the command 
> executor for pluggable containerization (see 
> https://issues.apache.org/jira/browse/MESOS-816).
> The escalation would need to prevent shutdown of the command executor until 
> child processes have actually stopped and if processes are still alive after 
> the timeout, send SIGKILL to the original process group.
> Further more, additional unit tests could be added to verify the new 
> escalation i.e. add or modify a test-executor so it becomes irresponsive to 
> SIGTERM and/or leaves behind orphan processes.



--
This message was sent by Atlassian JIRA
(v6.2#6252)

Reply via email to