Le 11/28/13 2:51 PM, Dhruv Chopra a écrit : > I understand how it will work with acceptors and binding to different > interface - I would like to know if someone has done it with MINA before > and could share their experience. To handle more than 65k+ concurrent tcp > clients (16 bit port range) - I will need such a setup.
No. you are limited to 65 000 ports for a specific cumple <client IP, server IP>, not to 65 000 connections. Your server can handle way more than 65 000 connections on one single address and one single port. Check http://stackoverflow.com/questions/2332741/what-is-the-theoretical-maximum-number-of-open-tcp-connections-that-a-modern-lin -- Regards, Cordialement, Emmanuel Lécharny www.iktek.com