https://issues.apache.org/jira/browse/TRINIDAD-2386?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13660065#comment-13660065
 ] 

Yee-Wah Lee commented on TRINIDAD-2386:
---------------------------------------

The date converter's _subparse method calls _accumulateNumber with maxLength=4. 
This means that years are at most 4 digits long. 

However, this is stricter than the server. Javascript accepts a wider range 
than 4 digit years, the range accepted is 6 digits long. 
http://stackoverflow.com/questions/11526504/minimum-and-maximum-date
                
> Client dateTimeConverter overly strict, restricts years to max 4 digits
> -----------------------------------------------------------------------
>
>                 Key: TRINIDAD-2386
>                 URL: https://issues.apache.org/jira/browse/TRINIDAD-2386
>             Project: MyFaces Trinidad
>          Issue Type: Bug
>            Reporter: Yee-Wah Lee
>            Priority: Minor
>
> 1. Go to 
> http://example.irian.at/trinidad-demo/faces/convertValidate/clientConvert.jspx
> 2. In the date converter, enter a date with 5 digit years, e.g. 5/31/20139
> 3. Click Submit -> get error about the date being in the incorrect format

--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators
For more information on JIRA, see: http://www.atlassian.com/software/jira

Reply via email to