Marco: Not sure if you are referring to the current mynewt LoRa implementation or LoRa in general. The Semtech SX1276 chip draws 11-12mA in receive mode. The processor will add to this of course. If you are asking about mynewt specifically the current drain has not been measured but there are quite a few GPIO turned on plus the HFXO and the processor running so it will be more than that.
The current drain will also change quite a bit based on the class of the LoRa device. Class C is constantly receiving. Class A is only receiving for a very short amount of time so the current drain will be considerably less. Lots of variables there; really only way to know is measure it. Will > On Nov 6, 2017, at 3:30 PM, Marco Ferreira <[email protected]> wrote: > > Hi everyone! > > Does any of you have an idea what's the power consumption for Rx with LoRa? > > Thanks > -- > Marco >