Yes, and you need to set the node address as well. We plan to update the documentation with this. Please keep the feedback coming! Thanks.
Sent from my iPhone > On Mar 20, 2015, at 4:00 AM, Oscar dela Pena <[email protected]> wrote: > > Hi, > > I remember having the same problem > > In my case, I had to assign correct hostnames for each node in the cluster > > In conf/nifi.properties, > > NCM node: > nifi.web.http.host=vbox1 > nifi.web.http.port=7070 > > Slave node: > nifi.web.http.host=vbox2 (leaving this blank makes NiFi bind to localhost) > nifi.web.http.port=7272 > > Let me know how your setup is and I'll try to check also. > > Owie > ----- Original Message ----- > From: "Corey Flowers" <[email protected]> > To: [email protected] > Sent: Friday, March 20, 2015 4:51:27 AM > Subject: Re: Having isues with NiFi cluster > > Have you verified that all the management ports are open? It maybe waiting on > a response from one of the nodes. If you would like, you could send me the > app and wrapper log and I will take a look. > > Sent from my iPhone > >> On Mar 19, 2015, at 7:05 AM, Kalisz, John T. <[email protected]> wrote: >> >> I set up a NiFi cluster based on the following Wiki: >> >> https://kisstechdocs.wordpress.com/2015/01/15/simple-tasks-in-nifi-creating-a-super-simple-cluster/ >> >> It is a three node cluster with one node (server) set up as the cluster >> manager and two other servers set up as nodes. >> When I start the cluster everything appears to work. There are no >> discernable errors in the log files and the two nodes are sending heartbeats >> to the master. When I try bring up the NiFi index page, I simply see a >> "loading" icon that never goes away. >> I also noticed that the heartbeats from the nodes are being generated at a >> significantly higher rate than the default setting of 5 seconds. >> >> Any guidance would be appreciated. >> >> John T. Kalisz >> General Dynamics Mission Systems >> >> Office 413-494-3376 | Cell 413-822-1883 | >> [email protected]<mailto:[email protected]> >> >> This message and/or attachments may include information subject to GD >> Corporate Policies 07-103 and 07-105 and is intended to be accessed only by >> authorized recipients. Use, storage and transmission are governed by >> General Dynamics and its policies. Contractual restrictions apply to third >> parties. Recipients should refer to the policies or contract to determine >> proper handling. Unauthorized review, use, disclosure or distribution is >> prohibited. If you are not an intended recipient, please contact the sender >> and destroy all copies of the original message. >>