https://issues.apache.org/jira/browse/ODE-263?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12603944#action_12603944
 ] 

Christoph M. Pflügler commented on ODE-263:
-------------------------------------------

Hi,

as I need this feature for my thesis, I tested it with Axis2.

The relevant BPEL part:
<scope name="timeout">
                <eventHandlers>
                        <onAlarm>
                                <for>'PT7S'</for>
                                <scope>
                                        <sequence>
                                        <throw faultName="TimeoutFault"/>
                                        </sequence>
                                </scope>
                        </onAlarm>
                </eventHandlers>
                <sequence>
                <receive partnerLink="testing" portType="testWsdl:testingPT" 
operation="testIt" variable="DataTOin" createInstance="yes">
                </receive>
                
                <invoke partnerLink="ws1" portType="testWsdl:ws1PT" 
operation="doIt" inputVariable="DataTOin" outputVariable="DataTOout">
                </invoke>
                
                <reply partnerLink="testing" portType="testWsdl:testingPT" 
operation="testIt" variable="DataTOout">
                </reply>
                </sequence>
</scope>

partnerLink ws1 would reply after 50 seconds, however I get the TimeoutFault 
message as reply from the process after the 7 seconds. So looks like it works 
with an Axis2 based deployment.

HTH,
Christoph

> onAlarm is trigered only after completed activity
> -------------------------------------------------
>
>                 Key: ODE-263
>                 URL: https://issues.apache.org/jira/browse/ODE-263
>             Project: ODE
>          Issue Type: Bug
>          Components: BPEL Runtime
>    Affects Versions: 1.1.1
>         Environment: FUSE ESB 3.3.0.2
>            Reporter: Mateusz Nowakowski
>             Fix For: 1.2
>
>
> Let say I have very short onAlarm eventHandler:
> <bpel:eventHandlers>
>         <bpel:onAlarm
>                         <bpel:for"PT5S"</bpel:for>
>                         <bpel:scope>
>                                         <bpel:throw  
> faultName="tns:TimeoutFault"/>
>                         </bpel:scope>                                         
>                   
>         </bpel:onAlarm>
> </bpel:eventHandlers>
> and process contains very long activity (invoke, flow etc.).
> Alarm is triggered only after very long activity completes, not after 
> specified amount of time.
> I tested it using invoke activity which invokes very long external web 
> service.
> ODE is launched using default async mode.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to