Hello Sebastian,

sorry for double post, but I would like to gain your attention at the
following problem:


if there is lot of users lots of users in the room (5-7) some of them can't
hear some others until "reload" of streams on the client.
Timur told me that according to the log of red5sip there is weird queue of
method calls: newStream gets called twice. Additionally if user has stream
with id 24 and select "reload" the following methods are gets called:
closeStream(25) // NOTE 25 not 24
then
newStream(25)

Maybe you can say what is wrong?

-- 
WBR
Maxim aka solomax