On Mon, Aug 13, 2012 at 4:02 PM, Ben Pfaff <b...@nicira.com> wrote: > On Wed, Aug 08, 2012 at 07:21:23PM -0700, Jesse Gross wrote: >> At the end of the NetFlow unit tests we warp time to force any >> remaining flows to expire and then immediately kill OVS and the >> collector. However, this creates a race where sometimes these >> processes are killed before the last records are sent or collected. >> It's possible to force OVS to go through the run loop one last time >> before exiting but it's harder to enforce that the collector receives >> the packet. This simply avoids the problem by adding a 1 second delay >> before killing the processes, which should be more than enough time. >> >> Signed-off-by: Jesse Gross <je...@nicira.com> > > Thanks, this looks good. Sleeping in the unit tests isn't ideal but > it's better than failing.
Thanks, I pushed this. _______________________________________________ dev mailing list dev@openvswitch.org http://openvswitch.org/mailman/listinfo/dev