https://issues.apache.org/jira/browse/PARQUET-2222?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17693881#comment-17693881
]
Gang Wu commented on PARQUET-2222:
----------------------------------
I think the reason is that *DataPageHeaderV2* has two fields to store them.
{quote}struct DataPageHeaderV2 {
// repetition levels and definition levels are always using RLE (without size
in it)
/** length of the definition levels */
5: required i32 definition_levels_byte_length;
/** length of the repetition levels */
6: required i32 repetition_levels_byte_length;
{quote}
> [Format] RLE encoding spec incorrect for v2 data pages
> ------------------------------------------------------
>
> Key: PARQUET-2222
> URL: https://issues.apache.org/jira/browse/PARQUET-2222
> Project: Parquet
> Issue Type: Bug
> Components: parquet-format
> Reporter: Antoine Pitrou
> Priority: Critical
> Fix For: format-2.10.0
>
>
> The spec
> (https://github.com/apache/parquet-format/blob/master/Encodings.md#run-length-encoding--bit-packing-hybrid-rle--3)
> has this:
> {code}
> rle-bit-packed-hybrid: <length> <encoded-data>
> length := length of the <encoded-data> in bytes stored as 4 bytes little
> endian (unsigned int32)
> {code}
> But the length is actually prepended only in v1 data pages, not in v2 data
> pages.
--
This message was sent by Atlassian Jira