https://issues.apache.org/jira/browse/PHOENIX-4550?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16336808#comment-16336808
 ] 

James Taylor commented on PHOENIX-4550:
---------------------------------------

The QualifierEncodingScheme is just an enum that identifies which encoding 
scheme we're using, right? It's not the complete set of columns and their 
column qualifier names.

We could potentially put the MAX_COLUMNS in that data structure, though 
(assuming we can work out b/w compat).

> Allow declaration of max columns on base physical table
> -------------------------------------------------------
>
>                 Key: PHOENIX-4550
>                 URL: https://issues.apache.org/jira/browse/PHOENIX-4550
>             Project: Phoenix
>          Issue Type: Improvement
>            Reporter: James Taylor
>            Priority: Major
>
> By declaring the max number of columns on a base table, we can optimize the 
> storage for SINGLE_CELL_ARRAY_WITH_OFFSETS by not storing null values for the 
> columns preceding the initial column of a view. This will make a huge 
> difference in storage when you have a base table with many views. For example:
> {code}
> -- Declare that the base table will have no more than 10 columns
> CREATE IMMUTABLE TABLE base (k1 VARCHAR, prefix CHAR(3) v1 DATE,
>     CONSTRAINT pk PRIMARY KEY (k1, prefix))
>     MULTI_TENANT = true,
>     MAX_COLUMNS = 10;
> CREATE VIEW v1(k2 VARCHAR PRIMARY KEY, v2 VARCHAR, v3 VARCHAR)
>     AS SELECT * FROM base WHERE prefix = 'A00';
> CREATE VIEW v2(k2 VARCHAR PRIMARY KEY, v2 VARCHAR, v3 VARCHAR);
>     AS SELECT * FROM base WHERE prefix = 'A10';
> ...
> {code}
> As the number of views grow, the difference between the base table column 
> encoding (column #1) and the starting column number of the view (since the 
> starting offset is determined by an incrementing value on the base table) 
> will increase. This bloats the storage as we need to store null values for 
> column encodings between the base table column and the starting column of the 
> view.
> Instead, we'll pass through the MAX_COLUMNS value for queries and anything 
> column encoding less than this we know it'll be at the start. Anything 
> greater and we'll start the search from <column encoding> - <minimum view 
> column encoding>.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to