patrickboisclair commented on issue #1156: URL: https://github.com/apache/plc4x/issues/1156#issuecomment-1772606716
Well works, let me explain: Passing a "new PlcXXX(value)" write a value to the PLC, but not the good one as mentionned above. Example: writing 1 writes 16777216 with this syntax. Passing a value without a "PlcTYPE" parameter, always writes null to the Plc -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: dev-unsubscr...@plc4x.apache.org For queries about this service, please contact Infrastructure at: us...@infra.apache.org