https://issues.apache.org/jira/browse/PROTON-1266?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Justin Ross updated PROTON-1266:
--------------------------------
Labels: reactor (was: )
> Reactor API does not allow to set maxFrameSize
> ----------------------------------------------
>
> Key: PROTON-1266
> URL: https://issues.apache.org/jira/browse/PROTON-1266
> Project: Qpid Proton
> Issue Type: Improvement
> Components: proton-j
> Affects Versions: 0.12.2
> Reporter: Michael Haeusler
> Labels: reactor
>
> There is currently no option to set the maxFrameSize of the Transport
> instance when using the Reactor API.
> In the server case the whole setup happens in the private AcceptorReadable
> class.
> In client case there is one option to subclass IOHandler and override the
> onConnectionLocalOpen(Event event) method, so that the max frame size can be
> set. However this requires that the onConnectionLocalOpen method of the
> parent class is never called.... which results in duplicate code and may
> diverge from the parent code when updating to a later proton-j version.
--
This message was sent by Atlassian JIRA