I have noticed dynamic alarm configuration, such as
‘alarm.default.alarm-settings‘ as ’Config Key’ . Where should I configure
the ‘Config Key‘?

Sheng Wu <[email protected]> 于2020年6月2日周二 下午6:48写道:

> No, it doesn’t have to be for all services. The document gives you the
> including and excluding ways.
>
> benchu yao <[email protected]>于2020年6月2日 周二下午6:46写道:
>
> > But oap is configured for all services
> >
> > I want to provide different alarm solutions for different services
> >
> > Sheng Wu <[email protected]> 于2020年6月2日周二 下午6:38写道:
> >
> > > You could do this on the OAP alarm settings, don’t need this at the
> agent
> > > side.
> > >
> > > benchu yao <[email protected]>于2020年6月2日 周二下午4:31写道:
> > >
> > > > The alarm is now configured on the collector.
> > > >  I want to ask if there is a method configured on the agent side,
> that
> > > is,
> > > > to provide different alarm thresholds for different services
> > > >
> > > > Thanks,
> > > >
> > > > Yao benchu
> > > >
> > > --
> > > Sheng Wu 吴晟
> > >
> > > Apache SkyWalking
> > > Apache Incubator
> > > Apache ShardingSphere, ECharts, DolphinScheduler podlings
> > > Zipkin
> > > Twitter, wusheng1108
> > >
> >
> --
> Sheng Wu 吴晟
>
> Apache SkyWalking
> Apache Incubator
> Apache ShardingSphere, ECharts, DolphinScheduler podlings
> Zipkin
> Twitter, wusheng1108
>