I'm not sure if this has always been the case (and I am just noticing
it now) or it started happening recently, but I noticed that there are
two more lines in the Configurations web console plugin for logging
than I would expect.

I see these options:
Apache Sling Logging Configuration (non-factory)
Apache Sling Logging Logger Configuration (non-factory)
Apache Sling Logging Logger Configuration (factory)
Apache Sling Logging Writer Configuration (non-factory)
Apache Sling Logging Writer Configuration (factory)

Apache Sling Logging Logger Configuration (non-factory) and Apache
Sling Logging Writer Configuration (non-factory) don't seem to have
corresponding ManagedService services. At least for the latter,
creating a configuration with that PID doesn't seem to invoke any
code.

Is this a typo in the metatype.xml? Or I missing some purpose behind
these entries?

screenshot here: http://screencast.com/t/xafmWeatwt

Thanks,
Justin

Reply via email to