Adityasharma created SLING-7902:
-----------------------------------
Summary: The http.conn.timeout property on
ForwardDistributionAgentFactory does not pick user entered values.
Key: SLING-7902
URL: https://issues.apache.org/jira/browse/SLING-7902
Project: Sling
Issue Type: Bug
Components: Content Distribution
Affects Versions: Content Distribution Core 0.2.10
Reporter: Adityasharma
As part of one of the projects we were trying to use Sling Content
Distribution. Whenever our package size grew to a number which took more than
10 seconds to process our distribution queue on the Author instance would go
into a blocked state and was irrecoverable from. We had to manually clean the
queue in order to proceed.
While trying to troubleshoot the issue we tried to increase the
http.conn.timeout but this did not take hold. While trying to debug the issue
further we came across the file ForwardDistributionAgentFactory and found that
this parameter was not being read from the configs and hence getting hard coded
to a default value of 10 seconds.
On further investigation we found its the same case with the Reverse/Sync
Distribution Agent Factory classes too.
--
This message was sent by Atlassian JIRA